PackSpecDocs Independent technical documentation of EU packaging law
Document status: verified against EUR-Lex OJ text Last review: 5 November 2026 Articles: 5(1), 5(4), 5(5), 16, 39 Applies from: 12 August 2026

Heavy metals and PFAS under Article 5(4) and Article 5(5)

Article 5 carries two different kinds of substance restriction into the new regime. Article 5(4) preserves the long-standing heavy-metal limit from the repealed Directive: lead, cadmium, mercury and hexavalent chromium, taken together, must not exceed 100 mg/kg in the packaging or in any packaging component. Article 5(5) introduces a new and structurally different restriction on per- and polyfluoroalkyl substances, and it applies only to packaging that comes into contact with food.

1. The heavy-metal limit

The four metals are summed, not assessed individually. A packaging component containing 60 mg/kg of lead and 45 mg/kg of cadmium is at 105 mg/kg and fails the test even though neither metal alone approaches a separate ceiling. The unit of assessment is the packaging or any of its components — which means that coatings, inks, adhesives, and coloured or foamed plastics must each be capable of being accounted for, and that a compliant carton board does not rescue a non-compliant printed layer.

The provision is a carry-over from Directive 94/62/EC, and that continuity is useful operationally: operators with existing test data may find that the underlying measurement still applies. What changed is the legal instrument. Under the repealed Directive the limit sat in a directive requiring transposition; under the Regulation it sits in a directly applicable article, enforced by market surveillance on a single legal basis across all Member States.

2. The PFAS restriction, and why its structure matters

Article 5(5) is not a single limit but a graduated set of thresholds, and the three figures measure different things. The distinction is the whole point of the provision: the first two catch deliberately used, identifiable substances, and the third catches total fluorine content regardless of whether the substance can be individually identified.

Table 1 — The three PFAS thresholds in Article 5(5), and what each measures
Threshold Basis of measurement What it catches Scope
25 ppb Targeted analysis, per individual PFAS Any single identifiable PFAS present above that concentration Food-contact packaging
250 ppb Targeted analysis, sum of PFAS The aggregate of identifiable PFAS, optionally after degradation precursors are accounted for Food-contact packaging
50 ppm Total organic fluorine, including polymeric PFAS All organically bound fluorine, whether or not the specific substance can be identified Food-contact packaging

Three operational consequences follow. First, a supplier declaration that says "PFAS-free" is not evidence: the provision is expressed in concentrations, and it is tested. Second, the 50 ppm total-organic-fluorine threshold means that a packaging which passes the targeted tests can still fail the article, because the fluorine is present in a form the targeted panel did not name. Third, the scope is food contact, and that scope is narrower than the market conversation around PFAS generally — a shipping carton for a non-food product is not within Article 5(5), while a food-contact liner inside it is.

3. Building a test programme that survives examination

The two restrictions in Article 5 differ in how they are evidenced, and a single test programme can satisfy both only if it is designed for the difference. Heavy metals are a fixed panel: four elements, a defined sum, a limit that has not moved in substance for two decades. PFAS are not a fixed panel. The targeted analysis covers named substances; the total organic fluorine figure covers the rest. An operator that commissions only the targeted panel obtains a result that speaks to two of the three thresholds and says nothing about the third.

Three design decisions determine whether the resulting evidence holds. The first is sample identity: the sample tested must be traceable to the packaging type declared, which means the laboratory submission must carry the specification reference and the batch, not merely the material name. The second is component coverage: because the heavy-metal limit applies to the packaging or any of its components, the programme must cover inks, adhesives, coatings and foamed or coloured plastics, not only the substrate. The third is currency: a result obtained for a specification that has since changed material or supplier is evidence about a packaging that is no longer on the market, and it will not withstand a file examination in which the declared specification and the tested specification have diverged.

Market surveillance operates on the file, not on the sample. Under Article 15(10) the manufacturer must be able to produce the documentation within ten days of a reasoned request, and Article 18(8) imposes the same window on the importer. A test report held by the supplier, referenced in the file but not retrievable, fails that test as surely as a report that was never commissioned. The practical standard is therefore not "we have the data" but "we can produce the data, for this specification, within ten days".

Verify the wording before relying on the table. The three figures above reflect the graduated structure set out in Article 5(5). The precise basis of measurement, the treatment of precursors and the reference methods are stated in the article and will be supplemented by the applicable analytical standards. An operator designing a test programme should work from the article text and the cited methods, not from this table alone.

3. Where the evidence goes

Neither restriction appears in the declaration of conformity as a figure. Article 39 records that conformity with the requirements laid down in or pursuant to Articles 5 to 12 has been demonstrated; the demonstration itself belongs in the Annex VII technical documentation. In practice this means the file must contain the test method, the sample identification, the laboratory result, and the link between the tested sample and the packaging specification declared. A result for an unnamed sample of the same nominal material is not evidence about a specific packaging type.

Article 16 is the provision that makes this achievable upstream: suppliers of packaging or packaging materials must provide the manufacturer with all the information and documentation necessary to demonstrate conformity. A supplier that cannot provide measured values is a gap in the manufacturer's file, not a supplier's private problem.

4. Article 5 Threshold Evaluator

The evaluator sums the four heavy metals against the 100 mg/kg limit and compares entered PFAS results against the three thresholds. It performs arithmetic on values you supply. It does not test anything, does not substitute for laboratory analysis, and does not determine compliance.

Article 5 Heavy Metals and PFAS Evaluator Enter measured concentrations · leave blank what you do not have
Heavy metals, in mg/kg of the packaging or component
PFAS results, food-contact packaging only

Enter at least one measured value. Each field is evaluated independently.

Arithmetic aid only. Not a test, not a conformity assessment, and not evidence for the Annex VII file. Article 5(4) and Article 5(5) of Regulation (EU) 2025/40.